苏州希普能塑料有限公司

A O

首页 > 产品中心 > PBT-聚对苯二甲酸丁二醇酯

VALOX 3706 - SABIC PC+PBT

VALOX 3706 - SABIC PC+PBT

SABIC VALOX™ 3706 Generic Name: Polycarbonate + PBT (PC+PBT)

现货报价:185 5121 3137 谭经理

VALOX™ 3706
Generic Name: Polycarbonate + PBT (PC+PBT) - Supplied by: SABIC
VALOX 3706 is an unreinforced impact modified flame retardant Polybutylene Terephthalate/Polycarbonate (PBT/PC) injection moldable grade. It has excellent chemical resistance and a UL94V0@1.5mm and 5VA@2.49mm flame rating. This is a good candidate for outdoor enclosures.
 
UL Yellow Card:E121562-100626858、E121562-220842、E121562-220843
Uses:Appliances、Construction Applications、Electric Vehicle (EV) Applications、Electrical Parts、Electrical/Electronic Applications、Electronic Displays、Lawn and Garden Equipment、Lighting Applications、Medical/Healthcare Applications、Outdoor Applications、Recreational Vehicle Applications
Availability:Latin America、North America
 
PHYSICAL Nominal Value Unit Test Method
Density / Specific Gravity 1.30 g/cm³ ASTM D792
Melt Mass-Flow Rate (MFR) (266℃/5.0 kg) 19 g/10 min ASTM D1238
Melt Volume-Flow Rate (MVR) (265℃/5.0 kg) 17 cm³/10min ISO 1133
Molding Shrinkage     Internal Method
Across Flow : 3.20 mm 1.2 to 1.4 %
Flow : 3.20 mm 1.2 to 1.4 %
MECHANICAL Nominal Value Unit Test Method
Tensile Modulus 2 1960 MPa ASTM D638
Tensile Strength 3     ASTM D638
Yield 48.0 MPa
Break 39.0 MPa
Tensile Elongation 3     ASTM D638
Yield 6.0 %
Break 50 %
Flexural Modulus 4 (50.0 mm Span) 1990 MPa ASTM D790
Flexural Strength 4 (Yield, 50.0 mm Span) 78.0 MPa ASTM D790
IMPACT Nominal Value Unit Test Method
Notched Izod Impact (23℃) 670 J/m ASTM D256
Instrumented Dart Impact (23℃, Total Energy) 49.0 J ASTM D3763
THERMAL Nominal Value Unit Test Method
Deflection Temperature Under Load     ASTM D648
0.45 MPa, Unannealed, 3.20 mm 126
1.8 MPa, Unannealed, 3.20 mm 85.0
Vicat Softening Temperature 135 ASTM D1525 5
CLTE     ASTM E831
Flow : -40 to 40℃ 7.9E-5 cm/cm/℃
Transverse : -40 to 40℃ 8.6E-5 cm/cm/℃
RTI Elec 100 UL 746B
RTI Imp 85.0 UL 746B
RTI Str 100 UL 746B
ELECTRICAL Nominal Value Unit Test Method
Arc Resistance 6 PLC 6   ASTM D495
Comparative Tracking Index (CTI) PLC 2   UL 746A
High Amp Arc Ignition (HAI) 8 PLC 0   UL 746A
High Voltage Arc Resistance to Ignition (HVAR) PLC 4   UL 746A
Hot-wire Ignition (HWI) PLC 2   UL 746A
FLAMMABILITY Nominal Value Unit Test Method
Flame Rating     UL 94
1.5 mm V-0  
2.5 mm 5VA  
INJECTION
Nominal Value Unit
Drying Temperature 120
Drying Time 3.0 to 4.0 hr
Suggested Max Moisture 0.020 %
Suggested Shot Size 40 to 80 %
Rear Temperature 240 to 255
Middle Temperature 245 to 260
Front Temperature 250 to 265
Nozzle Temperature 245 to 260
Processing (Melt) Temp 250 to 265
Mold Temperature 65 to 90
Back Pressure 0.300 to 0.700 MPa
Screw Speed 50 to 80 rpm
Vent Depth 0.025 to 0.038 mm
INJECTION NOTES
Drying Time (Cumulative): 12 hr

NOTES
150 mm/min
2Type I, 50 mm/min
31.3 mm/min
4Rate A (50℃/h), Loading 2 (50 N)
5Tungsten Electrode